Object directory
Communication profile area; index 1000 to 1FFF
Index
S-idx
Designation
1A01
0
Mapping
Trans PDO 2
1
the object
directory
2
the object
directory
3
the object
directory
4
the object
directory
Type
u32, ro
Index in
u32, ro
Index in
u32, ro
Index in
u32, ro
Index in
u32, ro
INPUT
Default
Description
0x04
Number of the application objects
linked with the Trans PDO 2
Idx 6401 SIdx 01 contains the value
0x6401 01
of channel 9.
type u16, original value, left-adjusted
(bit 15 = MSB, bit 6 = LSB)
For configured voltage input:
0 ... 10,000 mV
For configured current input
0 ... 20,000 µA
For configured ratiometric input:
-1000‰ ... 0 ... +1000‰
Idx 6401 SIdx 02 contains the value
0x6401 02
of channel 10.
type u16, original value, left-adjusted
(bit 15 = MSB, bit 6 = LSB)
For configured voltage input:
0 ... 10,000 mV
For configured current input
0 ... 20,000 µA
For configured ratiometric input:
-1000‰ ... 0 ... +1000‰
Idx 6401 SIdx 03 contains the value
0x6401 03
of channel 11.
type u16, original value, left-adjusted
(bit 15 = MSB, bit 6 = LSB)
For configured voltage input:
0 ... 10,000 mV
For configured current input
0 ... 20,000 µA
For configured ratiometric input:
-1000‰ ... 0 ... +1000‰
Idx 6401 SIdx 04 contains the value
0x6401 04
of channel 12.
type u16, original value, left-adjusted
(bit 15 = MSB, bit 6 = LSB)
For configured voltage input:
0 ... 10,000 mV
For configured current input
0 ... 20,000 µA
For configured ratiometric input:
-1000‰ ... 0 ... +1000‰
/