Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - IFM Electronic CR2513 Handbuch

Ecomat100 ein-/ausgangs-modul input
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

/
INPUT
OUTPUT MODULE

Technical data

Housing
Dimensions (l x w x h)
Mounting
Connection
Inputs
Outputs
can be configured as
Operating voltage U
B
Overvoltage
Current consumption
Operating temperature
Storage temperature
Protection
Interface
Baud rate
Communication profile
Node ID (default)
Status LED
Test standards
and regulations
Humidity
Mechanical resistance
Immunity to
conducted interference
Immunity to interfering
fields
Interference emission
28
PAGE
CR2513
closed screened metal housing with flange fastening
by means of 4 M5 x L screws to DIN 7500 or DIN 7984
mounting position horizontal or vertical to the mounting wall
55-pin connector, latched, protected against reverse polarity
AMP junior timer contacts, crimp connection 0.5/2.5 mm
4 digital; for positive switching sensor signals (Low Side)
4 analog; choice of absolute (0...10 V / 0...20 mA)
or ratiometric for potentiometric signal transmitters
incl. RC low-pass filter outputs for Danfoss valves (type PVEH/S/M)
(see also "Characteristics of the inputs/outputs", page 31)
IP 67 (for inserted plug with individually sealed cores e.g. EC2084)
10 Kbits/s ... 1 Mbits/s (default 125 Kbits/s)
CANopen, CiA DS 301 version 3.0, CiA DS 401 version 1.4
≤ 90 % rel. humidity, non-condensing, to IEC 68-2-30
to DIN 40839/part 1, pulses 1, 2, 3a, 3b (corresponds to ISO 7637)
to DIN 40839/part 1, pulses 5 (corresponds to ISO 7637)
to DIN 40839/part 3, pulses 1, 2, 3a, 3b (corresponds to ISO 7637)
132 x 43 x 153 mm
type AMP housing or Framatome
4
digital, positive switching (High Side)
analog, (PWM frequency 20...250 Hz)
10 ... 30 V DC SELV
36 V for t ≤ 10 s
≤ 100 mA (without external load)
-40°C ... +85°C
-40°C ... +90°C
CAN interface 2.0 B, ISO 11898
hex20 (= 32)
two-colour LED (red/green)
vibration to IEC 68-2-6
shock to IEC 68-2-27
bump to to IEC 68-2-29
severity level 4, function state C, A
severity level 1, function state C
severity level 4, function state A
guideline 95/54/EC to EN 50082-2
guideline 95/54/EC to EN 50081-1
2

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis