Alarm messages

The alarm messages in the table below are shown on the controller
display. These are accompanied by an audible alarm that can be ac-
knowledged and turned off by pressing any button on the controller.
Reporting Cause
P1
Room sensor error
Evaporator sen-
P2
sor fault
P3
Humidity sensor error Humidity control OFF
High tempera-
HA
ture alarm
Low tempera-
LA
ture alarm
HHA
Humidity HIGH alarm
LHA
Humidity LOW alarm
» Measure
Contact customer service (see Customer service, page 38).
Reporting Cause
Door alarm: Door
dA
open for a long time
» Measure
The message disappears as soon as the door is closed.
Reporting Cause
UVC lamp service
UCC
life reached
» Measure
see section UVC and activated carbon filter (page 38).

Maintenance

UVC and activated carbon filter
UV lamp
Type: HNS 5W 2G7 DX, power: 5W, voltage: 24V
radiant power > 0.16 W/m
The UVC lamp and the activated carbon filter must be replaced annu-
ally or as soon as the unit shows the warning message "UCC" on the
display.
Be sure to follow these maintenance guidelines. If the strength of the
UVC light is insufficient, it means that the unit is not working properly.
» Measure
Only order the original DRY AGER® UVC-replacement bulb (item
DX0101) and the active carbon filter (item no. DX0110) and change
both parts according to the information on the instructions supplied.
38
Outputs
Cooling and heating OFF
Defrosting after time. The
display alternately shows
the alarm message and the
actual temperature value.
Regulation unaffected
Regulation unaffected
Regulation unaffected
Regulation unaffected
Outputs
Regulation unaffected
Outputs
Regulation unaffected
@ 1m
2

Customer service

When contacting customer service, provide the type designation
the service number
, the service index
on the type plate.
The position of the type plate can be seen in the chapter Unit de-
scription (page 30).

Information about the unit

Enter the following information during the installation of the unit:
Type designation:
Service number :
Service index :
Series number :
Purchase date:
Dealer:

Disclaimer

The manufacturer assumes no liability for damage to the
refrigerated goods, even if the unit is defective within the warranty
period. The manufacturer also excludes liability for personal injury
caused by improperly stored goods that are subsequently placed on
the market.
and the serial number
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
,

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis