Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning; Preparation; Cleaning The Accessories; Cleaning The Interior - DRY AGER DX 1000 Premium S Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für DX 1000 Premium S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Cleaning

WARNING!
Always shut down the unit before cleaning. Pull
out the power supply plug or trigger or unscrew
the upstream fuse.
Do not use steam cleaning equipment!
Danger of damage and injury.
IMPORTANT
Do not use scouring pads. Do not use any abrasive
cleaning agents that contain acidic or chemical sol-
vents. First test the cleaner on a small area in an area
that is not clearly visible before cleaning the entire
unit.
Do not wipe stainless steel surfaces with dirty or
salt-contaminated wiping cloths, as this may result
in unsightly rust stains.
Make sure that no cleaning agent or cleaning water
penetrates the electrical parts and the ventilation
grilles (in the area of the bull heads and UVC steriliza-
tion). Do not use a sponge or cloth that is too wet.
The type plate on the inside of the unit must not be
damaged or removed. It is important for customer ser-
vice and any warranty claims.
Frequency of the cleaning process
Regularly clean the device and the accessories used by following the
cleaning steps 1.-5. below

1. Preparation

• Wear clean protective gloves.
• Remove all food from inside the unit and temporarily store in a
refrigerated area.
• Switch off the unit. Then pull out the power supply plug or trigger or
unscrew the upstream fuse.
• Remove the used accessories such as shelves, hangers, salt tray from
the unit.

2. Cleaning the accessories

• Clean the hanger, the shelves and the salt tray with water and a
suitable cleaning agent, such as DRY AGER® Special Cleaner.
• Clean other accessories according to the specified cleaning instruc-
tions.

3. Cleaning the interior

• Use a damp (lukewarm water + suitable agent such as DRY AGER
Special Cleaner) soft cloth or sponge to clean the inside of the unit.
• Thoroughly dry all parts with a soft cloth.
• Repeat the cleaning procedure if necessary.

4. Starting the cleaning program

• After each completed aging process, in addition to steps 1 to 3
above, the pre-cleaning program (P16) can also be activated. Dura-
tion: 2 hours.

5. Cleaning the outside

• Clean the door surface and the outer walls with a clean, soft cloth.
If necessary, a high-quality stainless steel and glass cleaner can be
used to clean the corresponding surfaces.

Troubleshooting

Malfunctions
The following malfunctions can be remedied by checking the possible
causes yourself.
• The unit does not work. Check if
- the unit is switched on,
- the power plug is correctly plugged into the socket,
- the fuse of the socket is ok.
• The noises are too loud. Check if
- the unit stands firmly on the floor,
- adjacent furniture or objects are vibrating as a result of the cooling
unit running. Please note that flow noise in the refrigeration circuit
cannot be avoided.
• The temperature is not sufficiently low. Check
- the setting according to section Setting the temperature (page 36).
Has the correct value been set?
- whether a independently inserted thermometer shows the correct
value.
- whether the ventilation is OK.
- whether the installation location is too close to a heat source.
• The condensation water freezes or does not run off in the con-
densation channel
- clean the drain opening with a suitable object
If none of the above causes exist and the fault cannot be rectified
yourself, please contact customer service (see Customer service,
page 38).
®
37

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis