Herunterladen Inhalt Inhalt Diese Seite drucken

Switching Times - INTORQ BFK458 Originalbetriebsanleitung

Elektromagnetisch gelüftete federkraftbremse
Vorschau ausblenden Andere Handbücher für BFK458:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical specifications
4.4

Switching times

The operating times listed here are guide values which apply to DC switching with rated air gap s
coil and standard characteristic torque. The operating times given are mean values and subject to vari-
ations. The engagement time t
Fig. 4:
Operating/switching times of the spring-applied brakes
t
1
t
2
M
dyn
Size
Rated torque
M
K
[Nm]
06
4
08
8
10
16
12
32
14
60
16
80
18
150
20
260
25
400
Tab. 10: Switching energy - operating frequency - operating times
1)
The maximum permissible friction energy Q
2)
These switching times are specified for usage of INTORQ bridge/half-wave rectifiers and coils with a connection
voltage of 205 V DC at s
INTORQ | BA 14.0168 | 08/2019
is approximately 8 to 10 times longer for AC switching. ...
1
M
M
dyn
U
Engagement time
Disengagement time (up to M = 0.1 M
Braking torque at a constant speed of rotation
1)
Q
S
E
hue
[J]
[1/h]
3000
79
7500
50
12000
40
24000
30
30000
28
36000
27
60000
20
80000
19
120000
15
and 0.7 I
.
LN
N
t
t
t
11
12
2
t
1
Delay time during engagement
t
11
)
Rise time of the braking torque
t
dyn
12
Voltage
U
DC-side engagement
t
11
[ms]
[ms]
15
15
28
28
17
27
33
65
100
110
120
relates to the standard friction lining.
E
t
t
2)
Operating times
Disengaging
t
t
12
1
[ms]
13
28
16
31
19
47
25
53
25
42
30
57
45
78
165
230
, warm
LN
t
2
[ms]
45
57
76
115
210
220
270
340
390
28

Werbung