Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Devices; Temperature Protection; Door Safety Switch; Uv Intensity Monitor - Henkel LOCTITE UVALOC 1000 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6

Safety devices

6.1

Temperature Protection

The lamp housing is provided with a thermo sensor for monitoring the temperature inside
the housing. This sensor is located on the PCB inside the lamp housing.
An error message is displayed whenever the temperature gets too high, and the
controller shuts the lamp off. As soon as the temperature is back to normal, the error
message indicated on the display can be reset and the lamp can be re-ignited.
This also happens when the system is too cold. It must first reach room temperature
before it can be put into operation.
Notice!
If the over-temperature protection has been tripped, check the ventilation slots and fans!
6.2

Door Safety Switch

When the exposure cycle is in progress, the door safety switch prevents opening of the
door while the shutter is open.
DANGER!
Removing, bypassing or putting out of operation of the safety devices can result in
radiation damage to persons and damage to the unit and is therefore prohibited!
6.3

UV Intensity Monitor

To control the bulb performance, a UV sensor is installed. The value of the intensity is
made in percent after each exposure and displayed on the screen.
A value for the UV minimum output can be adjusted in the menu.
If the bulb performance decreases below the adjusted value, the bulb should be
changed.
At the first installation a UV minimum value can be set. This value should be changed if
the required curing results are not achieved. This corrected value is valid for further
bulbs.
The error message "UV Minimum not achieved" is displayed at the controller. It will be
provided as an electrical signal also at the interface XS 2, see section 9.2.
7

Environmental Protection

7.1

Equipment

The unit may be returned to Henkel AG & Co. KGaA for disposal or dispose it in
compliance with the local regulations.
7.2

UV Bulb

CAUTION!
The bulb contains mercury or gallium. Do not dispose with household trash.
Disposal as hazardous waste is required. If there is no appropriate disposal site
available, return the lamp to Henkel after use.
36

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

9705597056