Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Components - Electrolux Dito K25 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
6.
ADJUSTMENT OF THE SAFETY DEVICES
2
• Check that the safety device is operating correctly on a regu-
lar basis. When the cover is opened, the motor should be
stopped by braking.
6.

ELECTRICAL COMPONENTS

3
6.
See electrical diagrams.
3
• Identification of the colours of the wires:
- Power circuit
- Control circuit
- Motor
:
(A) blue - (B) red - (C) black - (D) yellow
- Phases :
L Single phase
- Neutral :
N
- Earth
:
V/J yellow and green
6.
ADDRESS FOR SERVICE REQUIREMENTS
4
We advise you to contact the dealer who sold you the machine.
For any information or orders for spare parts, specify the
type of machine, its serial number and the electrical char-
acteristics.
• The manufacturer reserves the right to modify and make im-
provements to the products without giving prior warning.
Conformity with regulations
The machine has been designed and manufactured in con-
formity with:
- Machine directive 89/392 EEC
- The CEM directive 89/336 EEC
- To the European standards:
EN 60 204-1 - 1997 electrical equipment of machines
EN 292- 1+2, 1994 Machine safety devices, general design
principles
- To the French standards:
XPU 60010-1998 hygiene rules
NFU 64056-1985 fixed bowl cutters, integrated safety devices
This conformity is certified by:
- The CE conformity mark, attached to the machine
- The corresponding CE declaration of conformity, associated
with the warranty.
- This instruction manual, which must be given to the operator.
Acoustic characteristics:
- The acoustic pressure level measured in conformity with the
prEN 31201 test code is less than 70 dBA.
K 25 GB 11 99
: black
: red
• If this does not work:
- do not use the machine
- have it adjusted by the service department of your local dealer.
• Identification of the components:
O
: STOP button
I
: START button
P
: Continual pressure START button
S1
: Cover safety device
M1
: Single phase motor
KM1
: Contactor
K1A
: Auxiliary switch
CD/F : Start-up/braking condenser
CP
: Permanent condenser
K
: Klixon relay
B
: Terminal block
Dealer's stamp
Date of purchase:..............................................
• Protection indices as per the EN 60529-1991 standard:
IP55 electrical controls
IP34 overall machine
Integrated safety
- The machine has been designed and manufactured in com-
pliance with the relevant standards and regulations, mentio-
ned above.
- Before using the machine, the operator must be trained to
use the machine and informed of any possible residual risks
(personnel work station training obligation).
Food hygiene:
The machine is made from materials that conform to the
following regulations and standards:
- directive 89/109/EEC: materials and objects in contact with
foodstuffs
- directive 90/128/EEC: plastic materials in contact with food-
stuffs
The surfaces of the food area are smooth and easy to clean.
Use detergents that are approved for food hygiene andrespect
the instructions for their use.
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis