Herunterladen Inhalt Inhalt Diese Seite drucken

Signal Description Prc7000 Outputs - Bosch Rexroth PRC 7 00-L 403-Serie Typspezifische Anleitung

Process resistance welding control
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

34/42
Bosch Rexroth AG | Electric Drives and Controls
No.
PRC7000 Inputs
29
Not used
30
Not used
31
Not used
Spot selection Bit 00..31
32..63
Not used
64..71
Pressure feedback Bit 0 ..7
72..79
Not used
80..85
Proportional valve regulation OK
86
external
Proportional valve voltage OK
87
external
88..95
Not used
96..127
Production number Bit 0 - 31
No.
PRC7000 Outputs
Weld complete
0
Tip dress request
1
Prewarnung
2
End of stepper
3
4
Timer ready
5
Welding fault
6
Without monitoring / without
stepper
7
Weld
8
Start tip dress request
New electrode
9
Description
Transfer of the spot number
Pressure feedback, is passed on to the PU in order to carry out a
setpoint / actual value comparison, if necessary.
Feedback signal from prop valve control ok. If this bit = 0, the error
"Timer_Error_Propotional Valve" is set with the addition "PropValve
error in external control".
This error is self-acknowledging.
Feedback signal from prop valve voltage ok. If this bit = 0, the error
"Timer_Error_Propotional Valve" is set with the addition "PropValve
error in the external supply voltage".
This error is self-acknowledging.
The production number is entered in the Weld log.
6.3

Signal description PRC7000 outputs

Description
After an error-free welding cycle, the WC is set as long as the start
is set.
If no start is set after the process has been completed, the WC is
set for approx. 50 ms.
Is set if a dressing request or dressing is necessary.
Is set if a change request is pending.
Is set if electrode change is necessary.
Control is ready
Last process was finished with error.
Is reset with error reset.
Is set if no monitoring blocks or no readjustment are active.
External, global and spot-related weld on are switched on.
With new electrode and set electrode parameter "Start dressing"
this output is set.
With new electrode and not set electrode parameter "Start
dressing" this output is set.