Herunterladen Inhalt Inhalt Diese Seite drucken

Other Inputs And Outputs - Bosch Rexroth PRC 7 00-L 403-Serie Typspezifische Anleitung

Process resistance welding control
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

R911381576 | PRC 7x00-Lx/Wx-403
Plug
Output
A4
A5
A6
A7
Plug
1
2
3
4
5
6
7
XGM1
8
9
XGM2
5, 6
6, 7
XGM3
Plug
13,
14
XDS1
XGM2
1, 2
XGM3
9,10
Signal name
KSR selection 2
KSR selection 3
Not used
Not used
6.5

Other inputs and outputs

Other inputs
Tab. 11:
Input
Secondary current sensor ISEK_1
Secondary current sensor ISEK_2
Secondary current sensor shield
TEMP_1
TEMP_2
Transformer temperature shield
Secondary voltage USEK_1
Secondary voltage USEK_2
Secondary voltage shield
Analog pressure input
Analog force input
Other outputs
Tab. 12:
Output
Shunt release
Undervoltage release
Analog pressure output
Operate force sensor
Bosch Rexroth AG | Electric Drives and Controls
Description
This output is activated when a spot
has been selected to which a gun with
the numbers 10 to 19 has been
assigned.
This output is activated when a spot
has been selected to which a gun with
the numbers 20 to 29 is assigned.
Description
Secondary current
measurement
Transformer temperature
Secondary voltage
measurement
refer to Tab1. Required and
supplementary documentation,
Rexroth PRC7000 Process
Resistance Welding Control
Instructions
Description
refer to Tab1. Required and
supplementary documentation,
Rexroth PRC7000 Process
Resistance Welding Control
Instructions