3 Product description
2.4
Welding
• Arc welding may cause damage to the eyes, skin and hearing. Please
always wear the required safety clothing, eye and ear protection in
compliance with the relevant regulations in the country in question.
• Any metal vapors, especially lead, cadmium, copper and beryllium are
harmful! Ensure sufficient ventilation or extraction. Do not exceed the
current threshold limit values (TLV).
• Rinse workpieces that have been degreased with chlorinated solvents
using clean water to prevent the risk of phosgene gas formation.
Do not place degreasing baths containing chlorine in the vicinity of the
welding area.
2.5
Technical State
• Do not exceed the maximum limit values of the load data. Overloads
lead to destruction.
• Do not make any constructive changes to this device.
2.6

Protective clothing

• Do not wear loose fitting clothing or jewelry.
• Use a hair net for long hair.
2.7
Classification of the warnings
The warnings used in the operating instructions are divided into four different
levels and shown prior to potentially dangerous work steps.
DANGER
Describes an imminent threatening danger. If not avoided, this will result in fatal or extremely critical injuries.
WARNING
Describes a potentially dangerous situation. If not avoided, this may result in serious injuries.
CAUTION
Describes a potentially harmful situation. If not avoided, this may result in slight or minor injuries.
NOTICE
Describes the risk of impairing work results or potential material damage to the equipment.
2.8

Emergency information

In the event of an emergency, immediately disconnect the following supplies:
• Electrical power supply, compressed air supply, coolant supply and
gas supply.
3
Product description
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert and modify the device to enhance its performance without authorization.
3.1

Technical data

Transport and storage
Relative humidity
Type of use
Type of voltage
Polarity of the electrodes for DC
Tab. 1
General torch data (EN 60974-7)
EN - 36
−25 °C to +55 °C
Shielding gas (DIN EN ISO 14175)
Up to 90 % at 20 °C
Wire types
Voltage rating
Hand-held/automatic
DC
Protection type of the device
connections (EN 60529)
Usually positive
Control features in the handle
ABIMIG
• In connection with various welding torches, there may be other hazards,
for example those caused by: electrical current (power supply, internal
circuit), welding spatter with regard to combustible or explosive materials,
UV radiation from the arc, smoke and vapors.
• Adhere to the general fire protection regulations and remove flammable
materials from the vicinity of the welding work area prior to starting
work. Provide appropriate fire extinguishing equipment in the
workplace.
• During welding work outdoors, use suitable protection against the
weather conditions.
• During operation of the welding torches and in connection with the
welding process, always wear safety goggles, protective gloves and,
if required, a breathing mask.
Arranged in descending order of importance, they have the following
meanings:
Further measures can be found in the "Power source" operating instructions
or the documents for further peripheral devices.
®
A / A T / W / W T / MT
CO
and mixed gases M21
2
Commercially available round
wires
Peak value of 113 V
IP3X
For 42 V and 0.1 to 1 A
BAL.0835.0 • 2021-03-19