Insert the new Datamanager Card on
1
the Recerbo PC board
Datamanager Card:
Mount Datamanager PC board with 1
2
screw Taptite 4x8 TX20 (3)
[1.2 Nm]
Mount the antenna (2) using a wrench
3
[0.6 Nm]
Mount the 12-pin plug connection (1)
4
on the Datamanager PC board
Close the inverter and insert into the
5
wall bracket (see "Opening and Clo-
sing Device" section)
Datamanager Card 2:
Mount Datamanager 2 PC board with
2
1 screw Taptite 4x9 TX20 (3) [1.2 Nm]
Mount the antenna (2) using a wrench
3
[0.6 Nm]
Mount the 16-pin plug connection (1)
4
on the Datamanager 2 PC board
Close the inverter and insert into the
5
wall bracket (see "Opening and Clo-
sing Device" section)