Ensure the air is flowing into the
device!
Snap the new external fan into the air
1
ducts
Place the air duct on the rear of the
2
inverter
Feed in both fan cables and press in
3
the air ducts (4) on both sides
WARNING!
The seal plugs must be completely
inserted in order to ensure leak-tight-
ness
Snap in the locks (6) for the air duct
4
on both sides
Mount the air duct using two 5x14
5
TX25 screws (3)
[2.15 Nm]
NOTE!
Carefully turn the inverter around.
Plug in both fan cables (1) on the
6
SymoFIL and insert the lower cable
into the cable guide (2)
Close the inverter and place it in the
7
wall bracket (see "Opening and Clo-
sing the Device")
After switching on the inverter, carry out a
fan test via the display (see Operating
Instructions)