1 Measuring instrument
2 Inverter
9 Measuring lead
When carrying out the measurement (direct or differential current process), the ground
conductor current must not exceed the limit value of 3.5 mA **).
**) These requirements relate to DIN VDE 0701-0702 and ÖVE/ÖNORM E8701-1. In
addition, individual national requirements and standards must also be observed.

Contact Current

-
-
Measurements are taken between a grounded point and the touchable, conductive part
which is not connected with the ground conductor.
The contact current must not exceed 0.5 mA *).
1 Measuring instrument
2 Inverters
6.2 Touchable, conductive part not connected to the
ground conductor
8 Insulated assembly of the object being tested
9 Measurement leads
Ri 1 - 2 kW
118
PE
L1
N
9
9
9
PE
L1
N
2
Measurement should only be carried out once measurement of ground conductor
current has been carried out successfully
The device must remain in operation.
PE
L1
R i
mA
1-2kΩ
1
9
9
PE
L1
6.2
mA
1
Examples for measuring the ground conductor cur-
rent
N
N
2
8
6.2 Touchable, conductive part not connection to the
ground conductor