Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Datamanager Cardwlan Option - Fronius Symo 3.0-3-S Serviceanleitung

Vorschau ausblenden Andere Handbücher für Symo 3.0-3-S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Replacing the
Removing the Datamanager Card:
Datamanager
Card
WLAN Option
Installing the Datamanager Card:
(2)
(1)
(3)
WARNING!
Follow the safety rules (see start of
"Safety" chapter)
Remove the inverter from the wall bra-
1
cket and open (see "Opening and Clo-
sing Device" section)
Datamanager Card:
Loosen the 12-pin plug connection (1)
2
from the Datamanager PC board
Loosen the antenna (2) using a
3
wrench
Loosen 1 screw Taptite 4x8 TX20 (3)
4
Remove the Datamanager Card from
5
the Recerbo PC board
Datamanager Card 2:
Loosen the 16-pin plug connection (1)
2
from the Datamanager 2 PC board
Loosen the antenna (2) using a
3
wrench
Loosen 1 screw Taptite 4x9 TX20 (3)
4
Remove the Datamanager Card from
5
the Recerbo PC board