Herunterladen Inhalt Inhalt Diese Seite drucken

Fronius Symo 3.0-3-S Serviceanleitung Seite 106

Vorschau ausblenden Andere Handbücher für Symo 3.0-3-S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

(6)
(6)
(6)
NOTE!
To avoid applying mechanical stress to the modules, apply the torque in the same
sequence
(5)
(5)
(5)
106
(10)
(5)
(6)
(6)
NOTE!
Do not press on the marked area ==>
this will damage the PCM material
Remove three blister packs (10) at the
1
tabs of the new DuoPS and place on
the faulty DuoPS
CAUTION!
The PCM paste must not be damaged
(6)
or removed when inserting the DuoPS
Insert and position the new DuoPS
2
Mount the DuoPS modules using six
(6)
4x9 TX20 screws (6). Observe the tor-
que sequence to avoid applying
(7)
mechanical stress. First tighten all six
screws to [0.5 Nm] and then tighten
them to [2.0 Nm]
(6)
Mount the DuoPS using fifteen 4x9
3
TX20 screws (5) [2 Nm]
(5)
(5)
(5)

Quicklinks ausblenden: