Hang the power stage set cover up on
2
(5)
the fastening pins (5)
While the device is still at an angle,
3
pull the power stage set cover down
and swivel onto the base frame
CAUTION!
This is the only way to ensure that the
seal foam is correctly positioned and
working properly
Mount power stage set cover using
4
(4)
four 5x18 TX25 screws including gas-
kets (4)
[2.5 Nm]
(4)
NOTE!
If the screws no longer grip properly,
replace them with 5x25 TX25 screws
[42,0401,4231]
NOTE!
To avoid damage to the base shell, the
inverter must not exceed an angle of
11°.
(3)
Attach the inverter at the top and allow
5
it to engage with the wall bracket
Using two 5x25 TX25 screws (3), fix to
6
the wall bracket securely
[2.5 Nm]
If applicable, mount all plug connec-
7
tions
Mount Datcom lid using two 5x25
8
TX25 screws (2)
[2.5 Nm]
Set the DC disconnector (1) to the I
9
position
(2)