9 Maintenance and cleaning

9.1 Maintenance intervals

NOTICE
• The specified maintenance intervals are standard values and refer to single-shift
operation.
When using arc welding equipment, always observe the provisions of EN 60974-4 Inspection
and testing, as well as any national laws and regulations.
1
Proximity switch
Fig. 11
Weekly
Cleaning the device
• Clean entire device with
compressed air.
Checking proper functioning of
the sensor cable
• Check for proper functioning;
replace the sensor cable, as
needed.
Checking screws and pneumatic
hoses for secure attachment and
function
• Check for proper functioning;
replace, as needed.
EN - 22
2
Gripping clamp
Replacing the proximity switch
Monthly
Basic cleaning
• Clean device with
• Remove soiling with a
3
Cylinder head screws M4 × 10 (2 pieces)
compressed air.
clean cloth.
1
2
3
As needed
Replacing the welding
torch
• Safeguard the
welding system with a
light barrier/ "Stop"
mode/switching off
the control system.
• Replace the welding
torch manually during
shift changes.