6 Commissioning
6.3 Connecting the pneumatic system
NOTICE
Tab. 4 on page EN-8
• Use only original cleaned compressed air.
Connect the device according to the following pneumatic plan:
Fig. 6
Position of cylinder/valve
Z1 S1
Z1 S2
Z2 S3
Z2 S4
Y1 12
Y1 14
Y2 12
Y2 14
N1
N2
EN - 16
Connecting the pneumatic system
Description
Lift cylinder, lower end position
Lift cylinder, upper end position
Latching fork cylinder retracted
Latching fork cylinder extended
Retract valve for lift cylinder
Extend valve for lift cylinder
Retract valve for latching fork cylinder
Extend valve for latching fork cylinder
Fitting of the holding fork
6.4 on page EN-17
Cable assembly query
6.4 on page EN-17
MON.0015.0 • 2020-05-19