TROUBLESHOOTING

7.
TROUBLESHOOTING
PROBLEM
1. With the key at
«ON» the dashboard
remains off with no
audible signal.
2. With the key at
«ON» the dashboard
remains off, but there
is an audible signal.
3. With the key on
«START» the dash-
board comes on but
the starter motor does
not runa
4. With the key on
«START» the starter
motor runs but the
engine does not start
5. Starting is difficult
or the engine runs
erratically
6. Weak engine per-
formance during cut-
ting
LIKELY CAUSE
The protection of the electronic card has
cut in due to:
– badly connected battery
– battery terminals crossed
– completely flat battery or eroded bat-
tery plates
– fuse blown
– bad earthing to the engine or the frame
The protection of the electronic card has
cut in due to:
– electronic card wet
– earthed micro-switches
– insufficiently charged battery
– battery charger fuse blown
– badly earthed starter motor
– you are not ready for starting
– insufficiently charged battery
– faulty fuel supply
– faulty ignition
– fault in carburation
– forward speed too high in relation to
cutting height (☛ 5.4.5)
SOLUTION
Put the key in the «OFF» position and
look for the cause of the problem:
– check connections (☛ 3.4)
– check connections (☛ 3.4)
– recharge battery (☛ 6.2.5)
– replace fuse (10 A) (☛ 6.4.4)
– check connections of black earth
leads
Put the key in the «OFF» position and
look for the cause of the problem:
– dry using tepid air
– check connections
– recharge the battery (☛ 6.2.5)
– replace fuse (25 A) (☛ 6.4.4)
– check earth connections
– check that the conditions allowing
starting are met (☛ 5.2.b)
– recharge the battery (☛ 6.2.5)
– check the level in the tank (☛ 5.3.3)
– open the fuel stopcock (
(☛ 5.4.1)
– check the wiring of the fuel open com-
mand (
if fitted)
– check fuel filter
– check that spark plug caps are firmly
fitted
– check that the electrodes are clean
and have the correct gap
– clean or replace the air filter
– flush out the float chamber
– empty fuel tank and refill with fresh
fuel
– check and, if necessary, replace fuel
filter
– reduce the forward speed and/or raise
the cutting deck
EN 53
if fitted)