7. TROUBLESHOOTING

PROBLEM
1. With the key at «ON» the dashboard remains
off with no audible signal
2. With the key at «ON» the dashboard remains
off, but there is an audible signal
3. With the key on «START» the dashboard
comes on but the starter motor does not run
4. With the key on «START» the starter motor
runs but the engine does not start
5. Starting is difficult or the engine runs
erratically
LIKELY CAUSE
The protection of the electronic card has cut in
due to:
– badly connected battery
– battery terminals crossed
– completely flat battery
– fuse blown
The protection of the electronic card has cut in
due to:
– electronic card wet
– insufficiently charged battery
– battery charger fuse blown
– Faults in the charging circuit
– faulty fuel supply
– faulty ignition
– fault in carburation
SOLUTION
Put the key in the «OFF» position and look for the
cause of the problem:
– check connections (
3.4)
– check connections (
3.4)
– recharge battery (
6.2.3)
– replace fuse (10 A) (
6.3.5)
Put the key in the «OFF» position and look for the
cause of the problem:
– dry using tepid air
– recharge the battery ((
6.2.3)
– replace fuse (25 A) ((
6.3.5)
– contact Your Dealer
– check the level in the tank (
– check fuel filter
– check that spark plug caps are firmly fitted
– check that the electrodes are clean and have
the correct gap
– clean or replace the air filter
– flush out the float chamber
– empty fuel tank and refill with fresh fuel
– check and, if necessary, replace fuel filter
5.3.3)