8. TROUBLESHOOTING

PROBLEM
1. With the key on "START"
the starter motor does not
run
2. With the key on «START»,
the starter motor runs but
the engine does not start
3. Starting is difficult or the
engine runs
erratically
4. Poor engine performance
during cutting
5. The motor shuts down
whilst working
LIKELY CAUSE
Turn the key to pos. «OFF» and
look for the causes:
– conditions are not met to allow
starting
– badly connected battery
– battery terminals crossed
– completely flat battery or eroded
battery plates
– fuse blown (10 A)
– electronic card wet
– malfunction on the starter relay
– insufficiently charged battery
– faulty fuel supply
– faulty ignition
– fault in carburation
– forward speed too high
compared to cutting height
– the safety devices have cut in
– fuse blown (10 A)
SOLUTION
– check that the conditions allow-
ing starting are met (
– check connections (
– check connections (
– recharge the battery (
– replace the fuse (10 A)
(
6.3.5)
– dry using tepid air
– contact Your Dealer
– recharge the battery (
– check the level in the tank
(
5.3.3)
– open the fuel stopcock (if
present)
(
5.4.1)
– check the fuel filter
– check that spark plug cap is se-
curely fitted
– check that the electrodes are
clean and have the correct gap
– clean or replace the air filter
– empty the fuel tank and refill
with fresh fuel
– check and replace the fuel filter
if necessary
– reduce the forward speed and/
or raise the cutting deck
(
5.4.5)
– check that the conditions allow-
ing starting are met (
– replace the fuse (10 A)
(
6.3.5)
5.2.a)
3.4)
3.4)
6.2.3)
6.2.3)
5.2.b)