9.6  Warranty
Ottobock offers a comprehensive warranty on the basis of the current Genium service and warranty concept. For
details, please consult the Genium service pass (646D534=*) included in the scope of delivery. In the interests of
the medical supply company providing the fitting, the instruction of the patient and the transfer of the leg prosthesis
system must be confirmed by the patient in writing.
9.7  Technical Information
9.7.1  General
Ambient conditions
Operating, storage and transport temperature (in packaging):
Operating, storage and transport temperature (without packaging):
Battery charging temperature:
Relative humidity range:
Operating voltage of the battery charger:
Operating frequency of the battery charger:
Remote control charging cycles (battery) (charging and discharging cycles) af-
ter which at least 80% of the original battery capacity remains available:
Li-Ion battery charging cycles (joint) (charging and discharging cycles) after
which at least 80% of the original battery capacity remains available:
9.7.2  Knee joints
Designation
Proximal connection
Distal connection
Weight without tube adapter
Prox. system height to alignment reference point
Minimum distal system height
With 2R20/2R21 AXON Tube Adapter
Maximum distal system height
With 2R20/2R21 AXON Tube Adapter
Knee flexion angle
Frame material
Mobility grade
Max. body weight
Water resistance of the knee joint
9.7.3  AXON Tube Adapter
Designation
Weight
Material
Max. body weight
Water resistance of the AXON tube adapter
64 | Ottobock
64 | Ottobock
3B1
Pyramid adapter
0 mm
IPX4, protected against splashed water from any direction, but
not against submersion, jets of water or steam.
2R20
190-300 g/0.42-0.66 lbs
150 kg (330 lbs)
IPX4, protected against splashed water from any direction, but not
against submersion, jets of water or steam.
-10°C to +60°C
-10°C to +60°C
0°C to +45°C
up to 80 %
100 V to 240 V AC
50 Hz to 60 Hz
300
500
3B1=ST
Threaded connector
Tube clamp
1400 g / 3.09 lbs
26 mm
298 mm/330 mm
514 mm/546 mm
135°
Carbon
2, 3, 4
150 kg (330 lbs)
2R21 (torsion unit)
435-545 g/0.96-1.20 lbs
Aluminium
125 kg (275 lbs)