Herunterladen Inhalt Inhalt Diese Seite drucken

SATA SATAjet 1000 ROB RP/HVLP Betriebsanleitung Seite 424

Vorschau ausblenden Andere Handbücher für SATAjet 1000 ROB RP/HVLP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating Instructions for SATA ROB Automatic Guns
US
(see Chap. 13 for address).
Malfunc-
tion
Spray jet
uneven
424
Cause
Correc-
tive ac-
Paint nozzle
Retighten
not tight-
paint noz-
ened suffi-
zle.
ciently.
Air distri-
Replace air
bution ring
distribution
dirty or
ring (see
damaged.
Chap. 10.2).
Air nozzle
Tighten air
loose.
nozzle ring
hand tight.
Space
Clean in-
between air
termediate
and paint
space.
nozzle dirty.
Nozzle set
Clean noz-
dirty.
zle set.
Damaged
Replace
nozzle set
nozzle set
(see Chap.
10.1).
Spray me-
Check spray
dium flow
medium
pressure
flow pres-
not con-
sure.
stant.
Malfunc-
Cause
tion
Spritzbild
Bore in
zu klein,
air nozzle
schräg, ein-
clogged
seitig oder
with paint.
spaltet.
Paint nozzle
tip (paint
nozzle in)
damaged.
Proportion
of flat fan
air and
round fan
air not
equal.
Round/flat
Air distri-
fan control
bution ring
does not
incorrectly
work.
positioned.
Air distri-
bution ring
damaged.
Automatic
Nozzle set
gun does
is worn out.
not shut off
material.
Control pis-
ton collar or
paint needle
seal retain-
er is dirty or
worn.
Control air
pressure
present
constantly.
Correc-
tive ac-
Clean air
nozzle (see
Chap. 10.1).
Check paint
nozzle tip
for damage.
Replace
nozzle set,
if necessary
(see Chap.
10.1).
Correctly
adjust flat
fan air and
round fan
air (see
Chap. 9.1).
Position air
distribution
ring cor-
rectly (see
Chap. 10.2).
Replace air
distribution
ring (see
Chap. 10.2).
Replace
nozzle set
(see Chap.
10.1).
Clean con-
trol piston
seat. Re-
place seal
retainer, if
necessary
(see Chap.
10.4).
Relieve
control air
pressure.

Werbung