1.0

TECHNICAL DATA

MODEL 80 A
PRIMARY
Single phase supply
220 V
Frequency
Effective consumption
31A
Maximum consumption
49A
SECONDARY
Open circuit voltage
Cutting current
Duty cycle 40%
Duty cycle 80%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
EN 60974.1 / EN 60974.7 EN 60974.10
MODEL 120 A
PRIMARY
Single phase supply
220 V
Frequency
Effective consumption
52A
Maximum consumption
74A
SECONDARY
Open circuit voltage
Cutting current
Duty cycle 50%
Duty cycle 75%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
EN 60974.1 / EN 60974.7 EN 60974.10
2.0
CONTROLS: LOCATION AND FUNCTION
2.1 FRONT PANEL
Picture 1.
3
4
5
2
7
1
8
6
TECHNICAL DATA
230 V
380 V
400 V
50/60 Hz
29,5A
18A
17A
47A
28,5A
27A
232V
30 ÷ 80A
80A - 112V
50A - 100V
30A - 92V
IP 23
H
80 Kg
500 x 855 x 705 mm
230 V
380 V
400 V
50/60 Hz
50A
30A
28A
71A
42A
40A
232V
35 ÷ 120A
120A - 128V
85A - 114V
50A - 100V
IP 23
H
125 Kg
500 x 855 x 705 mm
1.
ON-SWITCH (Ref. 1 - Picture 1 Page 3.)
2.
PROTECTION - ON L.E.D. (Ref. 2 - Picture 1 Page 3.)
3.
INSUFFICIENT PRESSURE L.E.D. (Ref. 3 - Picture 1 Page
3.)
4.
RESET - BUTTON (Ref. 4 - Picture 1 Page 3.) This button
puts the power source back into service after completing the
torch servicing operation. When the shield cup is screwed on
the torch head, the L.E.D. (Ref. 5 - Picture 1 Page 3.) is off.
It's necessary to switch the button (Ref. 4 - Picture 1 Page 3.)
if you want to cut again.
5.
SHIELD CUP - L.E.D. DISCONNECTED (Ref. 5 - Picture 1
Page 3.)
6.
SWITCH REGULATION OF THE CUTTING CURRENT:
(Ref. 6 - Picture 1 Page 3.) In different positions the power
source supplies the specified cutting current.
7.
TORCH CONNECTOR (Ref. 7 - Picture 1 Page 3.)
8.
GROUND CABLE CONNECTOR (Ref. 8 - Picture 1 Page 3.)
3.0
INSTALLATION
IMPORTANT: BEFORE CONNECTING, PREPARING OR US-
ING EQUIPMENT, READ SAFETY REGULATIONS.
3.1
ELECTRIC CONNECTION.
This power source is supplied factory set for operation at 400V.
Before hooking it up to the power supply check that the mains volt-
age is compatible with the preset voltage, otherwise it is essential
to change the power source setting in accordance with the avail-
able supply voltage by means of the internal terminal board, which
is shown in the following diagram:
Make sure the mains socket outlet is equipped with a fuse rated
as shown in the following table:
Power supply
220V - 50Hz - 3ph
230V - 50Hz - 3ph
380V - 50Hz - 3ph
400V - 50Hz - 3ph
Make sure equipment air ventilation gates are not obstructed at all times.
3.2
AIR PRESSURE CONNECTION.
Connect the power source to the factory compressed air line by
means of the pressure reducer on the rear of the unit.
Compressed air supply
Flowrate
Minimum pressure
Maximum pressure
Working pressure
WARNING: CLEAN REGULARLY CONTROL FILTER TANK IN
(REF. A - Picture 2 Page 4.)
3 EN
Mod. 80A
Mod. 120A
Fuse 40A
Fuse 63
Fuse 40A
Fuse 63
Fuse 20A
Fuse 32
Fuse 20A
Fuse 32
220L/min
4,5bar
8bar
5,5bar