4.

Product description

4.1

Usage

FSA 050 can either communicate via Bluetooth
with computer that has FSA 7xx/500 software
(CompacSoft[plus]) installed or be used as a stand-
alone device.
The FSA 050 is designed for the performance of
insulation analysis on electric/hybrid vehicles. Voltage,
capacitance and resistance can also be measured.
4.2
Prerequisites for operation
with CompacSoft[plus]
Computer with operating system Windows 7,
Windows 8 or Windows 10 and at least one vacant USB
interface for the Bluetooth USB adapter. The current
version of CompacSoft[plus] must be installed on the
computer.
i
The FSA 050 has a Bluetooth transmission power
of 10 mW (Class 2) ex works. The Bluetooth class
can only be changed using the CompacSoft[plus]
software.
4.3

Scope of delivery

Designation
FSA 050
Case
Measurement leads (red/black) with
terminals (red/black)
Bluetooth USB adapter
Batteries (5x)
Calibration certificate

Remote sensor

CompacSoft [plus] DVD
Operating manuals
Robert Bosch GmbH
4.4
Fig. 1:
1 Red/black measurement leads
2 Red/black terminals
3 Remote sensor with test/zeroing button (TEST)
4 LCD
5 Function keys
6 Rotary switch for measurement functions
7 Rubber cover
4.4.1
The remote sensor can be used instead of the red
Order number
measurement lead. For insulation analysis, <TEST>
on the remote sensor has the same function as <TEST>
1 685 438 640
on the FSA 050.
1 684 430 075
The resistance of the black measurement lead and
the remote sensor can be zeroed for resistance
measurement (Ω).
Insulation analysis procedure with remote sensor:
1 684 430 074
1. Connect the black measurement lead to the black
1 687 370 275
negative socket of the FSA 050.
1 689 979 922
1 689 989 102
2. Connect the remote sensor to the 3-pin red
positive socket of the FSA 050 (instead of the red
measurement lead).
3. Connect the black measurement lead and the
remote sensor to the circuit to be tested.
4. Select the correct range (50 V, 100 V, 250 V, 500 V
or 1kV).
5. Press and hold <TEST> on the remote sensor.
 Insulation analysis is performed.
6. To terminate insulation analysis, release <TEST> on
the remote sensor.
Product description | FSA 050 | 25

Description of device

1
3
4
5
6
7
FSA 050
Remote sensor
1 689 989 102
en
2
|
2019-05-24