7.4. DEfROSTING
Manual defrosting occurs if the cabinet temperature is below parameter P57 (see tecincal manual).
To start a defrosting cycle press the
open. DISPLAY 1 indicates the code
(Fig.19)
7.5. STERILISATION (OPTIONAL)
Sterilisation can commence only if the temperature is above parameter P26 (see tecincal manual).
The cycle is activated with the machine in Stand-by by pressing the
When the button is pressed again, the cycle is terminated. The
that the sterilisation phase is in progress. DISPLAY 1 shows the time to the end of the process.
(Fig.20)
If the door is opened or a blackout occurs, sterilisation is interrupted (Fig.20).
7.6. PRINTER (OPTIONAL)
If the printer is present, the following is recorded for every blast chill cycle: date, time, type of cycle,
time elapsed from start of cycle and cabinet and core temperature sampled every 10 minutes.
For recording lower or higher than 10 minutes, change the parameter P44 (see tecincal manual).
Using parameter P86 (see technical manual) the language of the printer can be changed.
Time Ti SP1 SP2 SP3 SP4
00:00 25 54 52 51 49
00:10 8 45 44 42 40
7a.5. uSb RECORDER (optional)
This is present only if there is the expression code EVC99E00X0XXX00 (Optional).
Setting the parameter P41 = 2 allows the user to connect the USB Recorder interface (code EVUS
BREC01). When the keypad detects the presence of the USB Recorder, the user can access the USB
menu which provides information on the state of the USB Recorder by pressing the buttons
for 2 seconds:
When the USB flash drive is inserted in the USB Recorder, the progress of the ongoing operations
appears on the display. During a LOG DATA operation, the respective text with percentage of prog
ress appears:
When the operation has been completed correctly, the end is signalled:
Otherwise error states are signalled:
Pressing the button
During the data Upload operation, the user can interrupt the process by pressing the button
2 seconds.
To reset the USB Recorder, press the button
****HELLO****
03/03/2007
+3°C HARD
returns the user to the previous menu.
button for extended time with the machine in
and DISPLAY 2 the cabinet temperature (Fig.19).
Time
= time elapsed
Ti
= CAbINET temperature
10:15
SP1
= sensor 1 multi-point core probe point
SP2
= sensor 2 multi-point core probe point
SP3
= sensor 3 multi-point core probe point
SP4
= sensor 4 multi-point core probe point
for 2 seconds.
button.
symbol lit up on the display indicates
door
or
for