Wiring the power supply
Please connect the power supply to the clamps VDC1 and GND. The redundant
power supply shall be connected to VDC2 and GND.
The terminal block for the power supply is stackable and can be locked with two
screws. Futhermore, both voltage inputs have got a reverse polarity protection.
The voltage range for VDC 1 and VDC 2 is between 12 VDC and 70 VDC..
[Note] Please tighten the screws properly and check the correct holding
of all connections.
[Note] When wiring, please mind the appropriate cable cross-section of
at least 0,5mm² or 12 ~ 24 AWG.