38
10

Supplementary technical information

10.1 Run out and concentric tolerances

Hardness 46 ... 54 HRC
Surface quality of the run out and
0.8
concentric surfaces (A, B and AB)
Measuring range (NVm)
500
1 k
2 k
3 k
5 k
10 k
To ensure that the torque flange retains its characteristics once it is installed, we
recommend that the customer also chooses the specified form and position
tolerances, surface quality and hardness for the connections provided.
HBM
AB
Axial run out
AB
Rad. run out
Internal centering
Axial run out tolerance (mm)
0.01
0.01
0.02
0.02
0.02
0.02
B
A
Radial run out tolerance
(mm)
0.01
0.01
0.02
0.02
0.02
0.02