Nominal (rated) torque M
General data
EMC
Emission (per EN61326 1, Section 7)
RFI field strength
Interference immunity (per
EN61326 1, Table 2)
Electromagnetic field (AM)
Magnetic field
Electrostatic discharge (ESD)
Contact discharge
Air discharge
Rapid transients (burst)
Impulse voltages (surge)
Conducted interference (AM)
Degree of protection per EN 60529
Weight, approx.
Reference temperature
Nominal (rated) temperature range
Operating temperature range
Storage temperature range
Mechanical shock according to
5)
EN 60068−2−27
Number
Duration
Acceleration (half sine)
Vibration in 3 directions according to
5)
EN 60068−2−6
Frequency range
Duration
Acceleration (amplitude)
Nominal (rated) rational speed
Load limits (data applies to the
nominal (rated) temperature range)
Limit torque, related to M
Breaking torque, related to M
Longitudinal limit force
8)
Lateral limit force
Bending limit moment
Oscillation width per DIN 50100
9)
(peak to peak)
5)
Antenna ring and connector need to be fastened (construction example see Fig. 3.5, Page 17).
6)
Each type of irregular stress (bending moment, lateral or longitudinal force, exceeding nominal (rated) torque) can only be permitted up to its specified
load limit provided none of the others can occur at the same time. If this condition is not met, the limit values must be reduced. If 30% of the bending limit
moment and lateral limit force occur at the same time, only 40% of the longitudinal limit force is permissible and the nominal (rated) torque must not be
exceeded. The permissible bending moments, longitudinal forces and lateral forces can affect the measurement result by approx. 0.3% of the nominal
(rated) torque. The load limits apply only to the nominal temperature range. The load limits apply only to the nominal temperature range. At temperatures
t 10 C° load limits reduced by up to 30 % have to be allowed for because of increasingly reduced viscosity at decreasing temperatures.
7)
With static load.
8)
Static and dynamic.
9)
The nominal (rated) torque must not be exceeded.
HBM
N⋅m
nom
kN⋅m
V/m
A/m
Rotor
Stator
°
C [
°
C [
°
C [
°
C [
m/s
m/s
rpm
6)
7)
nom
7)
nom
8)
8)
N⋅m
N⋅m
500
1
kV
kV
kV
kV
V
kg
2.0
kg
1.1
°
F]
°
F]
+10 ... +70 [ +50 ... +158 ]
°
F]
−20 ... +85 [ −4 ... +185 ]
°
F]
−40 ... +85 [ −40 ... +185 ]
n
ms
2
Hz
h
2
20,000
%
200
%
> 400
kN
13
19
kN
4
5
200
220
1000
2000
2
3
5
Class B
10
100
8
4
1
1
10
IP 54
4.0
4.1
7.0
1.2
23 [ 73.4 ]
1000
3
650
10 ... 2000
2.5
200
15,000
12,000 10,000
160
> 320
30
35
60
9
10
12
560
600
800
8000
4000
4800
A2463 5.0 en/de
T40
10
12.0
1.3
80
18
1200
16000