• RAID Level 6 - Block-level striped disk array with dual distributed parity
– A RAID Level 6 hard disk drive group consisting of at least four hard disk drives
– Supported strip size: 8 KB to 1 MB
– Better performance and fault tolerance that can stand up to loss of two hard disk drives
– RAID Level 6 might not be available on all models of LSI MegaRAID adapter
Ensure that the LSI MegaRAID SAS adapter card is installed in your computer, and that the hard disk drives
are connected to this adapter card and not to the connectors on the system board.
Entering the LSI MegaRAID BIOS configuration utility
This section provides instructions on how to enter the LSI MegeRAID BIOS configuration utility.
To enter the LSI MegaRAID BIOS configuration utility, do the following:
1. During the computer startup, follow the instructions on the screen.
2. Press Ctrl+H to enter the CONTROLLER SELECTION window.
3. Select the controller you want to configure, and then click Start to enter the LSI MegaRAID BIOS
configuration utility.
Creating RAID volumes using the LSI MegaRAID BIOS configuration utility
This section provides instructions on how to create RAID volumes using the LSI MegaRAID BIOS
configuration utility.
To create RAID volumes using the LSI MegaRAID BIOS configuration utility, do the following:
1. Click Configuration Wizard on the WebBIOS main screen to enter the Choosing the Configuration
Type window.
2. Press the up and down arrow keys to select one of the three configuration types:
• Clear Configuration: Clear the existing configuration.
• New Configuration: Clear the existing configuration and create new configuration.
• Add Configuration: Retain the existing storage configuration and add new hard disk drives. The
new configuration will not cause any data loss.
3. Select Add Configuration, and then click Next. The following two options are displayed in the
Configuration Method window.
• Manual Configuration: Manually create hard disk drive groups and virtual hard disk drives, and
set parameters.
• Automatic Configuration: Automatically create an optimal RAID configuration.
4. Select Manual Configuration, and then click Next. The Drive Group Definition window is displayed. To
create hard disk drive groups, do the following:
a. Select one or more hard disk drives for the group (keep pressing Ctrl while selecting more than
one hard disk drive).
b. Click Add To Array to move the selected hard disk drives to Drive Groups.
c. Click Accept DG to create the hard disk drive group.
d. Repeat the above steps if you want to create more than one hard disk drive group.
5. Click Next. The Span Definition window is displayed. Select the hard disk drive group that you want
to add to a span, and then click Add to SPAN. Repeat this step until you have selected all the hard
disk drive groups you want.
.