5.3.2.3 Program C - ALU 1

For alloy rims with adhesive wheel weights below both
rim edges
2
4
The distance between machine and rim is automatical-
ly detected.
Extend the outside gauge to the position 3 and hold in
place until an audible signal is heard.
Replace the gauge back into its home position.
A further audible signal is heard for the con rmation that
the arm has reached ist home position.
BM 10-2
Enter rim diameter manually via the +/- button.
!
The actual value is automatically stored when ano-
ther button is pressed or the wheel guard is closed to
start the measuring run.
BM 11 / 20-2 / 30-2 / 40-2 / 50-2
The rim diameter is automatically detected together
with the distance by the inner gauge arm.
BM 10-2 / 11 / 20-2 / 30-2
The rim width is preset depending on distance and dia-
meter. Out of that the value for the rim width does only
has manually to be corrected a little or not entered at
all. The preset value for the rim width is displayed after
distance and diameter have been stored. The value
can be corrected by pressing the +/- button.
Measure the nominal rim width using the rim width gau-
ge or check the dimensions stamped on the rim.
Enter the value manually via the +/- buttons.
BM 40-2 / 50-2
Extend the outside gauge to the position 4 (see above)
and hold in place until an audible signal is heard.
Replace the gauge back into its home position.
Wheel data can also be entered by using the +/- keys.
1 689 979 917N
03.07.2013

5.3.2.4 Program D - ALU 2

For alloy rims with adhesive wheel weights below the rim
edge and on the inner side of the rim.
2
3
BM 10-2 / 11 / 20-2 / 30-2 / 40-2 / 50-2
The distance between machine and rim is automatical-
ly detected.
Extend the outside gauge to the position 2 and hold in
place until an audible signal is heard.
Move the inside gauge directly to position 3 and hold
until another audible signal is heard.
Return the gauge to the home position.
Another signal indicates that it is in the home position.
BM 10-2
Enter rim diameter manually via the +/- button.
!
The actual value is automatically stored when ano-
ther button is pressed or the wheel guard is closed to
start the measuring run.
BM 11 / 20-2 / 30-2 / 40-2 / 50-2
The rim diameter is automatically detected together
with the distance by the inner gauge arm.
!
The rim width is not of meaning in this balancing pro-
gram.