Herunterladen Inhalt Inhalt Diese Seite drucken

Mode Standard (12H); 5.3.2.1 Program A - Steel; 5.3.2.2 Program B - Static - Nussbaum BM 11 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für BM 11:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
5.3.2

Mode STANDARD (12h)

see also chapter 5.2 Program selection.

5.3.2.1 Program A - STEEL

For Steel- and alloy rims with clip on weights attached
to the rim edge
1
5
The distance between machine and rim is automatical-
ly detected.
Extend the outside gauge to the position 1 and hold in
place until an audible signal is heard.
Replace the gauge back into its home position.
Wheel data can also be entered by using the +/- keys.
A further audible signal is heard for the con rmation that
the arm has reached ist home position.
BM 10-2
Enter rim diameter manually via the +/- button.
!
The actual value is automatically stored when ano-
ther button is pressed or the wheel guard is closed to
start the measuring run.
BM 11 / 20-2 / 30-2 / 40-2 / 50-2
The rim diameter is automatically detected together
with the distance by the inner gauge arm.
BM 10-2 / 11 / 20-2 / 30-2 / 40-2 / 50-2
The rim width is preset depending on distance and dia-
meter. Out of that the value for the rim width does only
has manually to be corrected a little or not entered at
all.
The preset value for the rim width is displayed after di-
stance and diameter have been stored. The value can
be corrected by pressing the +/- button.
Measure the nominal rim width using the rim width gau-
ge or check the dimensions stamped on the rim.
Enter the value manually via the +/- buttons.
!
The actual value is automatically stored when ano-
ther button is pressed or the wheel guard is closed
to start the measuring run.
52
BM 40-2 / 50-2
Extend the outside gauge to the position 5 (see above)
and hold in place until an audible signal is heard.
Replace the gauge back into its home position.
Wheel data can also be entered by using the +/- keys.

5.3.2.2 Program B - STATIC

Static balancing i.e. for motorcycle wheels with only
one position for the balancing weights
3
The distance between machine and rim is automatical-
ly detected.
Extend the outside gauge to the position 3 and hold in
place until an audible signal is heard.
Replace the gauge back into its home position.
A further audible signal is heard for the con rmation that
the arm has reached ist home position.
BM 10-2
Enter rim diameter manually via the +/- Button.
!
The actual value is automatically stored when ano-
ther button is pressed or the wheel guard is closed to
start the measuring run.
BM 11 / 20-2 / 30-2 / 40-2 / 50-2
The rim diameter is automatically detected together
with the distance by the inner gauge arm.
!
The rim width is not of meaning in this balancing pro-
gram.
03.07.2013
1 689 979 917N