Deactivating transmitters

This function is used to disable a transmitter.
When a transmitter is disabled, all the alarms and faults are suppressed. In
measurement mode the measured value for that transmitter is replaced by the
word » disabled « in the display, e.g.
In measurement mode:
u
Press [
] key.
Enter password (for maintenance or configuration).
u
Press [
] key to change over to menu mode.
Display:
Use [ q ] or [ l ] key to select the » TRANSMITTER ACTIVE « option.
u
Press [
] key –
The display shows whether the transmitter with the lowest bus address is
active, e.g.:
Use the [ q ] or [ l ] key to call up all the other transmitters.
Use the [ k ] or [ j ] key to enable/disable the selected transmitter:
» j « (yes) = transmitter enabled,
» n « (no) = transmitter disabled.
To quit the function:
u
Press [
] key to quit the function and display the menu option again.
Menu mode