The control unit has a number of optional functions to enable the user to
add specific functionalities to the automation, thus personalising the prod-
uct according to special needs.
10 – AUTOMATION OPERATION ADJUSTMENT
To personalise operation of the automation, a number of functions can be
enabled or disabled, also with the option for modifications to settings as
required. The functions are:
• AUTOMATIC CLOSURE. When this function is enabled, at the end of
the Opening manoeuvre command by the user, the control unit automati-
cally closes the door again after a set time interval.
• MOVEMENT SPEED. This function enables entry of the required speed
of the automation implemented to move the door.
• SENSITIVITY TO OBSTACLES. During a manoeuvre, if an obstacle
accidentally stops door movement (a gust of wind, a vehicle, person etc.)
this function promptly detects the increase in motor stress to contract the
obstacle and activates immediate and brief inversion of movement.
• PRESSURE DISCHARGE. At the end of the Closing manoeuvre, after
the door has closed completely, the motor continues to "push" the door
for a brief interval, to ensure perfect closure. Immediately afterwards, this
function activates a very brief inversion of movement, to reduce excessive
pressure exerted by the motor on the door.
The values of these functions can be set according to personal require-
ments using the following procedure with a transmitter that has at least
one key already memorised on the control unit.
Note – During this procedure, each time a key is pressed the courtesy
light illuminates briefly.
01. Press and hold the keys "T1" and "T2" simultaneously on the trans-
mitter for at least 5 seconds, after which release.
The two leds (green and red) on the Control unit flash to indicate entry
to function programming mode (the leds continue to flash throughout
the procedure).
02. Press and hold a transmitter key (already memorised on that of the
control unit) for at least 1 second (the green Led emits one flash).
03. Then select one of the four functions available and on the transmitter
press the key associated with the function for at least 1 second (the
green Led emits one flash):
• Automatic closure = (press key "T1")
• Movement speed = (press key "T2")
• Sensitivity to obstacles = (press key "T3")
• Pressure discharge (= press key "T4")
04. Lastly, refer to Table 4, select the required value in correspondence
with the selected function and on the transmitter press the key asso-
ciated with the selected value for at least 1 second (the green and
red Leds emit one confirmation flash).
ADJUSTMENTS AND OTHER OPTIONAL FUNCTIONS
TABLE 4
AUTOMATIC CLOSURE
No closure —> (press key "T1")
Closure after 15 seconds —> (press key "T2")
Closure after 30 seconds —> (press key "T3")
Closure after 60 seconds —> (press key "T4")
MOVEMENT SPEED
Low Opening / Low closing —> (press key "T1")
Low Opening / Fast closing —> (press key "T2")
Fast Opening / Low closing —> (press key "T3")
Fast Opening / Fast closing —> (press key "T4")
SENSITIVITY TO OBSTACLES
High —> (press key "T1")
Medium high —> (press key "T2")
Medium low —> (press key "T3")
Low —> (press key "T4")
PRESSURE DISCHARGE
No discharge —> (press key "T1")
Minimum —> (press key "T2")
Medium —> (press key "T3")
Maximum —> (press key "T4")
Notes to Table 4:
– The Table states the values available for each of the 4 special functions
and the corresponding key to be pressed on the transmitter for selection
of the specific value.
– The factory settings are highlighted in grey.
11 – MEMORISING A NEW TRANSMITTER WITH
PROCEDURE IN THE VICINITY OF THE CONTROL UNIT
[with a transmitter already memorised]
A NEW transmitter can be memorised in the control unit memory without
acting directly on key P1 of the control unit, but by simply working within
its reception range. To use this procedure, an OLD transmitter, previously
memorised and operative, is required. The procedure enables the NEW
transmitter to receive the settings of the OLD version.
Warning – The procedure must be performed within the reception
range of the receiver (maximum 10-20 m from receiver).
01. On the NEW transmitter, press and hold the key to be memorised for
at least 5 seconds and then release.
02. On the OLD transmitter, slowly press the control key to be memo-
rised on the other transmitter 3 times.
03. On the NEW transmitter, press the same key pressed in point 01 once.
Note – Repeat the same procedure for each key to be memorised.
12 – DELETING DATA FROM THE CONTROL UNIT MEMORY
Data in the control unit memory can be deleted partially or totally as
required. To do this, the following procedures can be used, as required:
• Deletion of a command on a transmitter already memorised
• Deletion of other data memorised on the control unit
Deleting a command
on a transmitter already memorised
The following procedure enables deletion of a single command assigned
to a transmitter key from the control unit memory.