System Set Up

5.2 Connecting inputs/outputs

1
TBO.1
2
3
1
CNP1
(WHT)
4
3
5
6
F2
6.3A 250V
1
CNP4
1
TBO.2
1
3
(RED)
2
3
SW5
4
5
8
LED1
6
1
1
CNV1
TBO.3
1
SW4
(WHT)
5
2
6
3
1
4
5
SW3
6
LED2
7
8
8
1
1
TBO.4
LED3
2
SW2
3
4
8
5
1
1
6
CNIH
(ORN)
3
SW1
1
1
CNBC
CNBHT
8
(GRY)
(BLK)
3
3
FTC
1
LED4
CNBH
(WHT)
7
CN1A
CNW5
CNW12
(WHT)
(WHT)
(RED)
1
1
1
2
4
4
2 4 6 8 10 12 14
2 4 6 8 10 12 14
2
4
1
3
5
1 3 5 7 9 11 13
1 3 5 7 9 11 13
TBI.1
TBI.3
<Figure 5.2.1>

Signal inputs

Name Terminal block Connector Item
IN1
TBI.1 13-14
IN2
TBI.1 11-12
IN3
TBI.1 9-10
IN4
TBI.1 7-8
IN5
TBI.1 5-6
IN6
TBI.1 3-4
IN7
TBI.1 1-2
IN8
TBI.3 1-2
IN9
TBI.3 3-4
IN10
TBI.3 5-6
IN11
TBI.3 7-8
IN12
TBI.3 9-10
IN1A TBI.3 12-14
CN1A
*1. Set the ON/OFF cycle time of the room thermostat for 10 minutes or more; otherwise the compressor may be damaged.
*2. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts may be reduced.
*3. To turn on the boiler operation, use the main remote controller to select "Boiler" in "External input setting" screen in the service menu.
*4. Connectable electric energy meter and heat meter
● Pulse type
Voltage free contact for 12VDC detection by FTC (TBI.3 1, 3 and 5 pins have a positive voltage.)
● Pulse duration
Minimum ON time: 40ms
Minimum OFF time: 100ms
● Possible unit of pulse
0.1 pulse/kWh
100 pulse/kWh
Those values can be set by the main remote controller. (Refer to the menu tree in "5.10 Main remote controller".)
*5. As for the smart grid ready, refer to "5.6 Smart grid ready".
Wiring specification and local supply parts
Item
Name
Model and specifications
Signal input
Signal input
Use sheathed vinyl coated cord or cable.
function
wire
Max. 30 m
Wire type: CV, CVS or equivalent
Wire size: Stranded wire 0.13 mm² to 1.25 mm²
Switch
Non-voltage "a" contact signals
Remote switch: minimum applicable load 12V DC, 1mA

Thermistor inputs

Name
Terminal block Connector
TH1
CN20
TH2
CN21
THW1
CNW12 1-2 Thermistor (Flow water temp.)
THW2
CNW12 3-4 Thermistor (Return water temp.)
THW5
CNW5
THW6
TBI.2 3-4
THW7
TBI.2 5-6
THW8
TBI.2 7-8
THW9
TBI.2 9-10
THWB1 TBI.2 11-12
THWB2 TBI.2 13-14
Ensure to wire thermistor wirings away from the power line and/or OUT1 to 15 wirings.
*1. The maximum length of the thermistor wiring is 30 m. When the wires are wired to adjacent terminals, use ring terminals and insulate the wires.
The length of the optional thermistors are 5 m. If you need to splice and extend the wirings, following points must be carried out.
1) Connect the wirings by soldering.
2) Insulate each connecting point against dust and water.
19
1
When the wires are wired to adjacent terminals
CN01
2
(WHT)
4
use ring terminals and insulate the wires.
6
F1
10A 250V
1
CN3C
(BLU)
3
1
CNPWM
(WHT)
3
CNRF
(WHT)
CN105
(RED)
CNIT
(BLU)
CN22
1
(BLU)
2
CN108
CN21
CN20
(YLW)
(RED)
1
1
2
3
6
8
10
12
7
9
11
13
TBI.2
Room thermostat 1 input *1
Flow switch 1 input
Flow switch 2 input (Zone1)
Demand control input
Outdoor thermostat input *2
Room thermostat 2 input *1
Flow switch 3 input (Zone2)
Electric energy meter 1
Electric energy meter 2
Heat meter
Smart grid ready input
Flow sensor
1
pulse/kWh
1000 pulse/kWh
Solid wire: ø0.4 mm to ø1.2 mm
Item
Thermistor (Room temp.) (Option)
Thermistor (Ref. liquid temp.)
Thermistor (DHW tank water temp.) (Option) *1
Thermistor (Zone1 flow water temp.) (Option) *1
Thermistor (Zone1 return water temp.) (Option) *1
Thermistor (Zone2 flow water temp.) (Option) *1
Thermistor (Zone2 return water temp.) (Option) *1
Thermistor (Boiler flow water temp.) (Option) *1
Thermistor (Boiler return water temp.) (Option) *1
OFF (Open)
ON (Short)
Refer to SW2-1 in <5.1 DIP Switch Functions>.
Refer to SW2-2 in <5.1 DIP Switch Functions>.
Refer to SW3-2 in <5.1 DIP Switch Functions>.
Normal
Heat source OFF/ Boiler operation *3
Standard operation
Heater operation/ Boiler operation *3
Refer to SW3-1 in <5.1 DIP Switch Functions>.
Refer to SW3-3 in <5.1 DIP Switch Functions>.
*4
*5
10
pulse/kWh
Optional part model
PAC-SE41TS-E
PAC-TH011TK-E (5 m)/PAC-TH011TKL-E (30m)
PAC-TH011-E
PAC-TH011-E
PAC-TH011HT-E