4.2. Operation
When the running speed of the generating set has stabilised (approximately 3 minutes):
Check that the circuit breakers (fig A – No.6) are well depressed Press if necessary.
Connect the devices to be used to the electrical sockets (fig. A – No. 7) of the generating set.

4.3. Switching off

Stop & disconnect the devices from the electrical sockets (fig. A – No.9).
Allow the engine to run idle for 1 or 2 min.
Turn the starting & shut-down key (fig. A – No. 5) in the anticlockwise direction to position (A).
The generating set shuts down.
Always ensure sufficient ventilation for the generating set.
Even after stoppage, the motor continues to give off heat.
Warning
In case of key failure, stop the generating set and activate the stop lever (fig. A- No.10) and turn the starting & shut-down key in the
anticlockwise direction to position (A).

5. Safety features

5.1. Circuit breaker

The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
5.2. Oil cut-out
If there is no oil in the engine sump or if the oil pressure is low, the oil safety mechanism automatically stops the engine to prevent any
damage.
If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.

6. Maintenance schedule

6.1. Reminder of use
The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.

6.2. Maintenance table

Operations to be
carried out when
Component
the 1
Fastenings
Check the level
Engine oil
Oil filter
Fuel filter
Air filter
Battery
Generating set
Valves *
Fuel tank & pipes*
Spark arrester
* Operation(s) to be entrusted to one of our agents.
In case of use in dusty areas, clean the air filter more frequently.
In case of limited use, drain the oil every year at the latest.
Each time
st
due date is
it is used
attained
Check
Change
Replace
Replace
Check
Clean
Check
Clean
Check*
Clean*
Clean*
After:
st
1
month
Every
or
1 month
Every 10 hours
After:
Every
2 months
6 months
or
or
Every 50
Every 250
hours
Every
1 year
or
Every 500
hours
hours
•*
•*
•*