Herunterladen Inhalt Inhalt Diese Seite drucken

Description; Preparation Before Use; Checking The Oil Level - SDMO Diesel 6000 E XL C Benutzer- Und Wartungshandbuch/Übersetzung Der Original-Anleitung

Vorschau ausblenden Andere Handbücher für Diesel 6000 E XL C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
1.3.12 Safety guidelines for handling batteries
Danger

2. Description

1
Earth connection
2
Oil level gauge
3
Oil filler plug
4
Fuel tank plug
5
Starting and shut-down key
6
Solenoid valve
1
Oil gauge
2
Upper limit of gauge
1
Fuel tank exit hose
1
Nut for the air filter cover
2
Air filter cover

3. Preparation before use

3.1. Positioning the generating set for operation
Choose a site that is clean, well ventilated and sheltered from bad weather.
Place the generating set on a flat, horizontal surface which is firm enough to prevent the set sinking down (under no circumstances
should the set tilt in any direction by more than 10°).
Store the additional supplies of oil and fuel within close proximity, whilst maintaining a certain distance for safety.
3.2. Earthing the generating set
Danger
To connect the set to the ground: Attach a 10 mm
driven 1 meter into the ground.

3.3. Checking the oil level

Before starting the generating set, always check the engine oil level.
Top up with the recommended oil (see § Characteristics) using a funnel, up to the top limit of the gauge.
Allow the generating set to cool down for at least 30 minutes before checking the oil level.
Important
Remove the oil gauge (fig. A – No.2 & fig. B - No. 1) and wipe it.
Put back the oil gauge then take it out again. Visually check the level, it must be between the upper limit of the gauge
(fig. B – No. 2) & the lower limit of the gauge (fig. B – No. 3).
Top up if necessary using a funnel.
Put the oil gauge back in place.
Check that there are no leaks.
Wipe off excess oil with a clean cloth.
Never leave the battery close to a flame or fire.
Use only insulated tools.
Never use sulphuric acid or acid water to top up the electrolyte level.
7
Recoil-starter
8
Circuit breakers
9
Electrical sockets
10
Stop lever
11
Oil drain plug
12
Oil filter
3
Lower limit of gauge
4
Oil drain plug
Input & return hoses for the fuel
2
filter
3
Wing nut
4
Foam element
The generating sets supply electrical current when in operation: risk of electrocution.
Connect the generating set to the ground at each use.
2
copper wire to the set's earth connection and to a galvanised steel earthing rod
Figure A
Figure B
Figure C
Figure D
13
Fuel filter
14
Air filter
15
Starter battery
16
Exhaust silencer
5
Screw
6
Oil filter
3
Fuel filter screw
5
Paper element
6
Rubber gasket

Werbung