Herunterladen Inhalt Inhalt Diese Seite drucken

TERMA SKT 1 Gebrauchsanweisung Seite 58

Elektroheizpatrone
Vorschau ausblenden Andere Handbücher für SKT 1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.
Having set the address number, please wait a few seconds until the controller
returns to its normal function.
Please refer to the IR transmitter manual in order to find out how to adjust its
address.
FIL-PILOTE INTERFACE
Selected versions of SKT 4 are equipped with a FIL PILOTE interface which
enables remote heating control through an external controller which conforms with
FIL PILOTE standards.
SKT 4 reacts to all 6 commands:
Signal
FP Command
FP-COMFORT
FP-ECO
FP-AF
FP-STOP
FP-ECO1
3 s
300 s
FP-ECO2
7 s
300 s
It is also possible to use the Timer mode while the device reacts to the FP
commands. Timer mode is superior, therefore the device will work according to the
Timer's parameters. It will return to executing FP commands on termination of the
Timer mode.
Reaction of the controller
Heating in accordance with current
setting
Reduction of setting by 3°C (or 3 levels
in heat output regulation mode)
No heating, anti-freeze function is active
('F' code shows on the display panel)
Heating mode and anti-freeze functions
are both off
Reduction of setting by 1°C (or 1 level
in heat output regulation mode)
Reduction of setting by 2°C (or 2 levels
in heat output regulation mode)
TROUBLESHOOTING
Problem
Possible cause
Device is connected to
Connection problem.
electricity, it is turned
on but the display
screen is off.
Device does not heat,
Device informs of
E1 or E2 is flashing
emergency, temperature
on the LED screen.
sensor has been
damaged.
Possible incorrect
installation of the controller
on the heating element.
LED screen shows
Device works correctly
only the horizontal
(see: REMOTE MODE
line.
OPERATION)
Device switched from
Communication problem:
the remote to the
IR communication window
local mode on its own
may be covered in one of
accord.
the devices or the devices
are not correctly set.
Device heats despite
Electronics damage
having been turned
off with the ON/OFF
button.
Problem solution
Check power lead is
connected. Check if the
controller uptakes correct
voltage
Disconnect the device
completely from electricity
and wait for the radiator to
cool down. Connect it and
turn it back on again.
Check if the controller has
been correctly connected
to the heating element
(controller casing should
cover the head of the
heating element)
Remove any obstacles
causing communication
interference or place the
IR transmitter in a different
location.
Disconnect the device
completely from electricity
and wait for the radiator to
cool down. Connect it and
turn it back on again.