6.
Put the radiator back in an upright position and check the level of the liquid
inside it.
7.
Make sure that the connection between the radiator and the heating element is
tight.
8.
Install the controller – fit the indents on the head (A) with the indents in the
controller (B).
9.
Position the controller casing in a way providing an easy and comfortable
access.
WARNING! If you feel resistance when twisting the controller it means that you
have reached the maximum twisting span in that direction. Try to twist the controller
in the opposite direction. Any damage to the device will result in annulment of the
warranty.
Correctly installed controller entirely covers the head of the heating
element (see drawing)
10
12
10. Secure the casing at the back with Allen key.
11. Connect the device to electricity and turn on the heating element unit (upper
collector opening must be open!).
12. Set the maximum possible temperature required and observe the liquid level
rise – the excess liquid may be slopping through the upper opening – remove
excess liquid in order not to allow for the heating element unit to be flooded or
wetted.
13. When level of the heating medium stops rising, wait another 5 minutes, turn off
the heating element unit and disconnect the device from electricity.
14. Do not wait until the radiator cools down and pour a small amount of the liquid
out – to the mid level of the top pipe.
15. Close the upper opening of the collector with a dedicated seal and put it back
on the wall.
16. Connect the heating element unit to the socket / installation. The device is
ready to work.
DUAL FUEL radiator:
1.
Radiator connected to central heating system to which heating element unit is
installed additionally.
2.
Central heating installation must be fitted with the valves enabling
disconnecting the radiator from the rest of the system.
3.
It is recommended to bleed the radiator after every longer interval in use. The
device is fitted with a safety tool protecting the radiator from operating in dry
conditions, however, it will operate correctly only when the radiator is correctly
filled.
4.
Heating element must not be installed horizontally or turned downwards.
Tools required for installation of heating element unit
– Allen key no 1.5 (included)
– spanner no 24
Installation of the heating element unit
WARNING! The device must not be connected to electricity during
installation. Unlug the device prior to installation.
A
1
2 3
1.
In case of a radiator connected to central heating system, close both valves
and remove the heating medium.

Quicklinks ausblenden: