5
Electrical connection of the P2VA1/A2
Supply voltage 15 to 30 V DC
Supply voltage 0 V
Output 0.5 to 10 V (4 to 20 mA for the P2VA2)
Output 0 V
Transducer identification TEDS DATA
5
4
1
P2V
An external amplifier is connected to the P2V in accor
dance with Fig. 5.1.
Notice
The inputs and outputs of the P2V are protected against
short circuits and reverse polarity.
1)
2)
Connections 2 and 3 are internally linked.
3
1)
Operating on a SELV circuit (separated extra-low voltage)
2)
also ground for TEDS
2
Fig. 5.1
A1564-7.0 HBM: public
Electrical connection of the P2VA1/A2
1
3
4
2
5
Pin assignment of the P2V
brown
blue
Connection
black
cable wire
white
assignments
gray
13