Mechanical installation
12
pressure connection directly to conventional high pres
sure pipes with their 58° taper.
CAUTION
During installation, screwing torque must not be applied
over the enclosure or the cable entry. Wrenches (SW 24)
must be used to screw-fasten the pressure transducer.
The permissible tightening torque for measuring ranges
100 ... 2000 bar is 30 Nm; for measuring ranges 3000
and 7000 bar, the permissible tightening torque is 30 ...
50 Nm
DANGER
Before removing the P2V pressure transducer, you must
check that the line is not pressurized.
A1564-7.0 HBM: public
P2V