Installation instructions, only for experts

4.1. Installing the sauna control unit

Refer to Fig. 1 (page 11).
1. Remove the temperature selector 1.
2. Press the clip lock 6 in lightly using a screwdriver and remove
the cover from the housing.
3. Screw one cross-head screw (20 mm) into the wall of the sauna
at a height of approx. 1.70 m at a distance of up to 7 mm.
4. Fasten the sauna control unit onto the cross-head screw using
the attachment device b as an aid.
5. Guide the wires for the heater sensor through the cable bushing 4.
6. For optional door monitoring only:
Guide the wires of the door monitoring through the cable bushing 4.
7. Guide the heater, power supply and light cables through the cable
bushing 7.
8. Screw two cross-head screws (20 mm) into the lower fastening
holes 3 and 8.
9. Ensure that the sauna control unit is fitted securely.

4.2. Connecting wires

Refer to Fig. 1 (page 11) and Fig. 3 (page 15).
1. Connect the white wire for the sensor heater to terminal F1 on
the terminal strip 2; it is not necessary to ensure correct polarity.
2. Connect the red wire for the sensor heater to terminal TS on the terminal
strip 2; it is not necessary to ensure correct polarity.
3. For optional door monitoring only:
Remove the jumper wire from the terminal DR on the terminal strip 2
and connect the wires for the door monitoring.
4. Connect the heater, power supply and light cables (Fig. 3) to the terminal
strip 9 in accordance with the connection diagram.
5. Connect all available earth conductors on the earth conductor panel 5.