Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance Intervals - Abicor Binzel ROBO Compact W600 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für ROBO Compact W600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
ROBO Compact W600

9.1 Maintenance intervals

Several times a day
Clean weld spatter from the torch head. In
the case of heavy weld spatter build-up,
clean during each welding break.
• Clean the ROBO Compact W600
using an ABICOR BINZEL torch
cleaning station. Then spray with
ABICOR BINZEL anti-spatter fluid.
Tab. 11
Maintenance and cleaning
9.2 Wire guide
NOTICE
• The specified maintenance intervals are guidance values and refer to
single-shift operation.
When using arc welding equipment, always observe the provisions of
EN 60974-4 Inspection and testing, as well as any national laws and
regulations.
Check the following:
Weekly
We recommend basic cleaning
once a week. The type and
frequency of cleaning shall be
determined and established by
the operator of the welding
system.
Optional wire brake
• Clean the wire brake once
or twice, depending on wire
quality.
 9.5 Cleaning the wire
brake (optional version
with wire brake) on
page EN-23
Each time the wire guide is changed (liner, PA liner), make sure to consult the
product information in the instruction leaflets provided.
9 Maintenance and cleaning
Monthly
• Check that the
connections (cable
assembly, control lead,
ground) are secure.
Tighten if necessary.
EN - 19