9 Maintenance and cleaning

9 Maintenance and cleaning
Under normal operating conditions, the robot welding power source iROB Pulse does not require
maintenance. Scheduled maintenance and cleaning, however, is a prerequisite for a long life and a trouble-
free operation.
Risk of injury due to unexpected start-up
The following instructions must be adhered to for the entire duration of maintenance, servicing, mounting,
dismounting and repair work:
• Switch off the power source.
• Close the gas supply.
• Close off the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• Maintenance and cleaning work may only be carried out by qualified personnel
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• Please observe the operating instructions of the welding components, coolant recirculator iROB Cool
9.1 Maintenance intervals
NOTICE
• The maintenance intervals given are standard values and refer to single-shift operation.
Observe the instructions given in EN 60974-4 „Inspection and test during the operation of arc welding
equipment" and the laws and guidelines valid in the respective country.
Check the following:
Daily
Check all cables, connecting hoses and
connections for damage, replace them if
necessary.
General condition
Install the robot welding power source
maintaining a circumferential clearance of
50 cm to ensure optimum circulation of the
cooling air.
Tab. 11
Maintenance intervals
EN - 20
DANGER
DANGER
(in Germany see TRBS 1203).
(option), wire feeder iROB Feed (option), remote control iROB Control (option) and welding torch.
Monthly
Check all mobile parts and roll bearings for
correct functioning and replace them, if
necessary.
iROB Pulse
Quarterly
Both fans, replace them if necessary.
BAL.0323.0 • 2017-08-31