100
Hinweise zur
elektromagnetischen
Verträglichkeit (EMV)
Guidance and manufacturer's declaration – electromagnetic immunity – for equipment and systems that are not life-supporting
®
UNIDRIVE
S III ARTHRO model 28 7230 20-1 is intended for use in the electromagnetic environment specified below.
The customer or user of the UNIDRIVE
Immunity test
IEC 60601 test level
Conducted RF disturbance
acc. to IEC 61000-4-6
150 kHz to 80 MHz
Radiated RF disturbance acc.
to IEC 61000-4-3
80 MHz to 2.5 GHz
Note 1: At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection by structures, objects and
people.
a
Field strengths from fixed transmitters, such as base stations for radio [cellular/cordless] telephones and land mobile radios, amateur radio, AM and FM
radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters,
an electromagnetic site survey should be considered. If the measured field strength in the location in which the unit is used exceeds the applicable RF com-
pliance level above, the unit should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary,
such as reorienting or relocating the unit.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Electromagnetic
Compatibility (EMC)
Information
Table 4
®
S III ARTHRO model 28 7230 20-1 should assure that it is used in such an environment.
Compliance level
3 V
3 V
rms
rms
3 V/m
3 V/m
(
Electromagnetic environment - guidance
Portable and mobile RF communications equipment should
be used no closer to any part of the UNIDRIVE
ARTHRO model 28 7230 20-1, including cables, than the
recommended separation distance calculated from the
equation applicable to the frequency of the transmitter.
Recommended separation distance:
f
f
80 MHz to 800 MHz
h
800 MHz to 2.5 GHz
Where P is the maximum output power rating of the transmit-
ter in watts [W] according to the transmitter manufacturer
and d is the recommended separation in meters [m].
Field strengths from fixed RF transmitters, as determined by
a
an electromagnetic site survey
, should be less than
the compliance level in each frequency range