Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Maintenance And Cleaning - Abicor Binzel iCAT mini ABIROB G Serie Betriebsanleitung

Roboterhalterung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

iCAT mini

7 Operation

8 Decommissioning

9 Maintenance and cleaning

BAL.0361.0 • 2017-05-05
4 Shorten the wire guide on the front side by dimension a (2).
Shorten it so that it is slightly tight after installation.
5 Insert the wire guide in the cable assembly until it reaches the stop and
secure with set screw M4 × 5 (3).
Since the iCAT mini is integrated in the torch's welding process, the operating
steps are performed after the respective torch and the welding power source
has been put into operation. Observe the operating instructions of the relevant
welding torch.
Decommissioning depends on the respective welding torch. Observe the
operating instructions of the relevant welding torch and welding power source.
Scheduled maintenance and cleaning are prerequisites for a long service life
and trouble-free operation.
DANGER
Risk of injury due to unexpected start
The following instructions must be followed during all maintenance,
servicing, assembly, disassembly, and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and
damage.
• Replace any damaged, deformed or worn parts.
7 Operation
EN - 19

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Icat mini abirob g350

Inhaltsverzeichnis