6 Commissioning
6.3.2 Model with wire brake
1
2
12
1
Hole 1
2
Hole 2
3
Bellows
4
Wire brake
Fig. 9
Mounting the cable assembly—model with wire brake
EN - 16
3
5
Plastic tube
6
iCAT mini release flange
7
Cable assembly flange
8
Machine-side connection
The cable assembly is guided through the mounted robot mount.
1 Disassemble the push-in fitting (9) if already mounted.
2 Mount the cable assembly in mounting direction.
3 Mount the cable assembly with seven cylinder head screws M4 × 20 (12)
to the iCAT mini. Max. tightening torque 4 Nm.
4 Tighten the push-in fitting ø 6 using the screw-in aid AF11 (10).
5 Insert the shielding gas hose (11) and connect it to the shielding gas supply.
4
5
9
Push-in fitting
10 Screw-in aid AF11
11 Shielding gas hose
12 7 cylinder head screws M4 × 20