GB
Measuring range
Overpressure limit
Accuracy
Measuring range
Overpressure limit
Accuracy
Measuring range
Overpressure limit
Accuracy
Measuring range
Overpressure limit
Accuracy
Measuring range
Overpressure limit
Accuracy
Measuring range
Overpressure limit
Accuracy
Types of pressure
Pressure connection
Pressure medium
Temperature range
Temperature coefficients
Current
Measuring range
Resolution
Accuracy
Temperature
Measuring range
Resolution
Accuracy
Environmental
Operating Temperature
Storage Temperature
Power Requirements
Battery
Battery Life
Material
Wetted parts
Housing
Dimensions
Weight
ATEX approval
Entity Parameters
CE conformity
EMC directive
1
Non-Isolated: The measuring ranges w hich are thus marked are to be used exclusively w ith clean and non-corrosive gases.
2
The maximum static pressure for 25 mbar gauge is 70 mbar; for 70 mbar, 350 mbar and 500 mbar is 7 bar
12
Model CPH65I0
1
mbar
-25 ... +25
-70 ... +70
mbar
70
200
FS
0.1 %
0.05 %
1
bar
-1 ... +1
-1 ... +2
bar
2
4
FS
0.025%
0.025 %
bar
0 ... 1
0 ... 2
bar
2
2
FS
0.025 %
0.025 %
bar
0 ... 100
0 ... 200
bar
200
400
FS
0.025 %
0.025 %
bar abs
0 ... 1
0 ... 2
bar abs
300
300
FS
0.025 %
0.025 %
12
mbar diff
0 ... 25
0 ... 70
mbar diff
70
200
FS
0.1 %
0.05 %
Relative, absolute, vacuum and differential pressure
1/8" NPT female
All liquids and gases compatible with 316 stainless steel
°C
15 ... 35
0.002 % of FS per °C outside the range of 15 ... 35 °C
0 ... 24 mA
1 μA
0.015% of rdg ±0.002mA
-40 ... +150 °C
0.01 °C
0.015 % of reading ± 20 mΩ, or 0.2 °C for complete measuring chain
(Pt100 resistance thermometer and CPH65I0)
-10 °C ... +45 °C
-20 °C ... +60 °C
6 V DC, four (4) standard AA cells
> 35 hours, typical usage
316 stainless steel
stainless steel and plastics
21.1 x 9.9 x 4.6 cm
g
approx. 570
Ex ia IIB T3 Gb (Ta=–10... +45°C)
KEMA 10 ATEX *****
II 2 G Ex ia IIB T3 Gb (Ta=–10... +45°C)
IECEx CSA *******
MEASUREMENT JACKS:
Ui = 30 V; Ii = 80 mA; Pi = 750 mW; Ci = 0 μF; Li = 0 mH
Uo = 7,14 V; Io = 1,12 mA; Po = 2 mW; Co = 240 μF; Lo = 1 H
LEMO connector: For use with LTP100A RTD probe only
2004/108/EC, EN 61326 Emission (Group 1, Class B) and Immunity (portable measurement
equipment)
1
1
-350 ... +350
-500 ... +500
700
1000
0.035 %
0.035 %
1
0 ... 7
0 ... 20
14
40
0.025 %
0.025 %
0 ... 350
0 ... 700
700
1000
0.035 %
0.035 %
0 ... 7
0 ... 20
300
300
0.025 %
0.025 %
12
12
0 ... 350
0 ... 500
700
1000
0.035 %
0.035 %
1
WIKA Operating Instruction, Model CPH65I0
1
0 ... 35
0 ... 70
70
200
0.025 %
0.025 %
12
1