Chapter 6. Machine adjustment and setting up

6.1. Adjustment

6.1.1. Control panel

The machine is fitted with a control panel, from which all programming and operation functions can be set.
Q1 Main switch
B
Sealing warning light
C
Warning light of belt advancing time
D
Pause warning light
E
Warning light of over belt speed
F
Temperature warning light
P
Programs selection button
D1
Display. Displays selected functions and relative settings
S
Variables selection switch
G1 Button "DECREASE". Reduces set function values
G2 Button "INCREASE". Increases set function values
R
Reset button
D2
Piece counter display
S0
EMERGENCY Pushbutton: if pressed, the machine will stop immediately
S1
Start button
S2
Selector MAN.-AUT.
ELECTRONIC BOARD FEATURES
The machine is equipped with 5 selectionable programs:
Program no.
Program features
Cutting only
P1
Cutting + belt advancing (no shrinking)
P2
Complete programs
P3, P4, P5
Each program is composed by 6 variables which can be modified (in case it is not possible to set one of them, such a
variable will obviously not appear on the display):
Variable
1. Time for sealing
2. Pause time for lowered frame
3. Pause time for automatic cycle
4. Tunnel belt speed
5. Sealing belt time
6. Temperature
The machine is equipped with a piece counter to show on display (D2) the number of sealings.
Such a value can be put to zero at any time through reset button (R).
Field
Field features
0 ÷ 2.7
values expressed in seconds
0 ÷ 9
two tenth-seconds values each point
0.0÷ 9.9
values expressed in seconds
00 ÷ 99
0.0 ÷ 3.0
values expressed in seconds
00 ÷ 99
corresponds to 200°  398°C (2°C each point)-(medium value 75)