Connection diagram
A
B
1 Mains connection
A
B
C
2 Wastewater pump
D
E
F
3.7

Connection of a potential-free contact

A potential-free contact can be connected to the control unit, available from Busch-Jäger (art. no. 1515 U-12)
For this purpose the alarm key <6> and the pump key <8> must be pressed simultaneously for 5 seconds
after the control unit has been connected to the mains power supply
The control unit bleeps briefly twice as confirmation that the potential-free contact can be connected.
Connect the potential-free contact to O P in accordance with the circuit diagram Fig. [14].
3.8

Connection of the audible alarm

To connect the audible alarm again, keep the alarm key <6> and the pump key <8> simultaneously
for 5 seconds
The control unit bleeps briefly 3 times as confirmation that the audible alarm can be connected.
C
D
E
F
1
2
brown
blue
green/yellow
green/yellow
blue
brown
Installation
-
-
I1
I2
G
H
J
K
3
Ill. [14]
3 Float switch
G
yellow
H
white
J
pink
K
brown
L
grey
M
green
N
not occupied
4 Alarm
O
Connection for external
audible alarm/
P
potential-free contact
46 / 180
-
-